Asked by Strauss (23627points) August 27th, 2016 from iPhone

The large surface elements went out on my glasstop range. I ordered the replacement elements, and installed them per instructions. The right front element works fine, but nothing on the left. Upon troubleshooting, I determined that the infinity switch for that element was also defective. I ordered the switch and just installed it. No power to the element. Continuity readings are good across the switch and the element. What would my next troubleshooting step be